Cassette Assembly Roller
Assembly roller is designed for the plastic cassettes compression. After the test strips loaded into the plastic bottom cassette, align the upper cassette with the bottom cassette, then place them onto the assembly roller conveyor, it will be pressed and closed by the rubber roller at the end of the conveyor. It is suitable for the batch production of cassette and other similar products
Programmable Strip Cutter ZQ2002 ZQ2402
This series cutter mainly are used for cutting immunoassay uncut sheet into test strips with specific width. At the same time, it can also be used to cut dry chemical test paper, dry biochemical test paper or other materials. It is suitable for small and medium rapid test strips manufacturers and research users.
Technical Parameters:
- Maximum cutting speed: 240 times/minute
- Cutting width: 0.50-8.00 mm
- Cutting precision: ±0.05mm
- Material residual: 12 mm
- ZQ2002 maximum Width of uncut sheet: 98mm
- ZQ2402 maximum Width of uncut sheet: 128mm
- Equipment dimension: 420 x 390 x 280mm
XYZ Platform Dispenser HM3030/HM3035
The equipment is a high-tech product researched and developed by Kinbio, which integrates membrane dispensing and gold spraying as a whole. HM3030/HM3035 platform is driven by the motor at X axis (vertical position), Y axis (horizontal position) and Z axis (position of dispensing tip and platform height). 3D positioning is conducted by inputting the number into the operating interface, in order to achieve the reagent coating effect. HM3035 builds Vacuum adsorption platform and automatic conversion module that shift between dispensing and spraying..
- Dispensing efficiency: 200—300 sheets (30cm) /hour
- Spraying efficiency: 700~900 strips (30cm)/hour
- Platform moving speed: 50—200mm/s
- Platform (working) area:540X150(320X140)mm
- Dispensing tips minimum interval:3mm
- Dispensing tips distance adjustment: Stepless adjustment by screw rod
- Dispensing pump standard capacity: 500ul
- Spraying pump standard capacity: 1000ul
- Dispensing reagent concentration:0.2-9.99ul/cm
- Spraying reagent concentration:1.0-9.99ul/cm
- Minimum fill and drain volume:1ul
- Reagent residual volume: 0
- Dispensing tip position precision:±0.1mm
- Equipment dimension:540X450X350mm
- Equipment weight:28KG
Continuous Dispenser HM8008
HM8008 achieves dual-pump alternating dispensing. The conveyor belt in special design may intermittently dispense on one piece of backing card, or continuous dispense membrane on the reel backing card. It may also be connected with the reel to card laminator CTM650..
- HM8008 dispensing efficiency:1400-2000 sheets (30cm)/ hour
- Speed:50-200mm/s
- Dispensing tip minimum interval:3mm
- Sheet width:5-12cm
- Positioning precision:±0.10mm
- Minimum fill and drain volume:1uI
- Dispensing pump standard volume:500ul
- Dispensing Concentration:0.2-9.99ul/cm
- Equipment dimension:750X400X400mm
Sample Processor JPY300
The equipment is used for the pretreatment of glass fiber and polyester fiber in the production of Immunoassayphy rapid tests. It is consists of three parts: feeding platform, reagent tank and upper and lower pressure roller. Firstly, the sample pad is fed into the reagent tank through the feeding platform and is absorbed in the reagent slot. The processed sample pad is driven by a stepping motor, and then the excess reagent is extruded out after through the upper and the lower pressing rollers. It has the advantages of simple structure, convenient operation and uniform treatment, which greatly improves the processing efficiency of the sample pad..
Superuniform spherical gold nanoparticles
Introduction
Gold nanoparticles, with their excellent conductivity, stability, biocompatibility, and surface optical properties, have irreplaceable roles in optics, catalysis, electronics, immunodiagnosis, biosensors, biological imaging, and drug delivery. At present, sodium citrate reduction method is a classic method for preparing gold nanoparticles, but the prepared gold nanoparticles have irregular shapes, and their uniformity and stability are not ideal. Therefore, the preparation of gold nanoparticles with different particle sizes that have regular shapes, uniform particle sizes, good dispersibility, and stable properties is an urgent problem to be solved in current production. We first used chemical reduction method to prepare 5-15 nm small diameter super uniform spherical gold nanoparticles. Using small diameter spherical gold nanoparticles as seeds, we used seed growth method to prepare 20-200 nm super uniform spherical gold nanoparticles. The spherical gold nanoparticles prepared by this method have uniform particle sizes, regular shapes, and uniform dispersion; Depending on the particle size, it presents different colors in aqueous solution, such as orange, red, magenta, and brick red.
Preparation of gold nanoparticles with different particle diameters
Methods:
Prepare 5 to 15 nm super uniform spherical gold nanoparticles with chemical reduction method. Using 15 nm gold nanoparticles as seeds, prepare 20 to 200 nm super uniform spherical gold nanoparticles with seed growth method.Then characterize the prepared gold nanoparticles.Conclusion
- Uniform particle diameters, regular shape, small coefficient of variation
- Stable quality, stored at 4 ℃ for 2 years
- The production capacity is sufficient, with a batch capacity of up to 2000L, ensuring a stable batch capacity of up to one million liters per year.
- Customizable according to user needs
- The colloidal gold solution can be ordered with particles diameter from 10 to 80 nm, with minimum order of 20 ml.
Consumabales Kit For Rapid Test Producing
After the verification and analysis, Kinbio recommends and provides the consumables packages and set with high fitness and complete specifications for the clients engaged in the rapid tests manufacturing industry from the professional perspectives, including backing card, glass fiber membrane, polyester fiber membrane, absorbent paper. The strict consumable tracking management system is formulated to avoid the product instability caused by the difference in consumable batch and meet the customers’demand.
see more
Conventional:300*20mm/kit(5pcs)、300*25mm/kit(5pcs)
Bulk specification:100*20mm、100*25mm
Product Parameters
- A. Physical test data
- Polyester backing thickness(μm):105
- Membrane thickness(μm):110
- Membrane bursting strength(psi):45
- Membrane color: pure white
- Capillary action speed (s/4cm):85
- Protein binding degree (μg/c㎡):48
- (Bovine serum protein,pH=7.4)
- Strip cutting effect: no film edge damage
- Membrane width(mm):25 or 20
- Storage conditions: 15-28 ℃
- Shelf life: one year
B. Functional test
C. Dimension test
Special Packing Material For Immunochromatography
Special packing material for immunochromatography In addition to supplying professional consumables and kits and in order to meet different needs of customers, Kinbio also supplys special packaging materials for immunochromatography, including various reagent tubes, droppers, reagent cassettes, aluminum foil pouches, etc.